Installing VMware ESXi 6.0 Update 2 on the Intel Skull Canyon NUC6I7KYK requires some specific BIOS settings. Here are the settings used with BIOS 0034.
BIOS\Devices\USB |
Default |
ESXi 6.0 Update 2 install
|
USB Legacy |
On |
Disabled
|
Portable Device Charging Mode |
Charging Only |
Disabled
|
USB Ports (Port -01-08) |
Enabled |
Enabled
|
BIOS\Devices\SATA |
Default |
ESXi 6.0 Update 2 install
|
Chipset SATA |
AHCI |
Disabled
|
Chipset SATA |
S.M.A.R.T. |
Disabled
|
HDD Activity LED |
On |
Disabled
|
M.2 PCIe SSD LEG |
On |
Disabled
|
BIOS\Devices\Onboard Devices |
Default |
ESXi 6.0 Update 2 install
|
Audio |
On |
Disabled
|
LAN |
On |
On
|
Thunderbolt Controller |
On |
On (I did disable it for the install as part of my Stop error troubleshooting}
|
WLAN |
On |
Disabled
|
BlueTooth |
On |
Disabled
|
Near Field Communicattion |
Disabled |
Disabled
|
SD Card |
Read |
Read/Write
|
Legacy Device Configuration |
Default |
ESXi 6.0 Update 2 install
|
Enhanced Consumer IR |
On |
Disabled
|
High Precision Event Timers |
On |
Disabled
|
Num Lock |
On |
Disabled
|
Performance\Processor |
Default |
ESXi 6.0 Update 2 install
|
Real-Time Performance Tuning |
On |
Disabled
|
Power |
Default |
ESXi 6.0 Update 2 install
|
Performance Selection |
Balanced Enabled |
Max Performance
|
Secondary Power Setting |
Header text |
Header text
|
Intel Ready Mode Technology |
On |
Disable
|
Power Sense |
On |
Disable
|
After Power Failure |
Stay Off |
Power On
|